Skip to main content
1 Day + ExamNext intake 5th October 2026EAL

BAFE SP203-4
Emergency Lighting Course.

For electricians and fire-safety installers who need the EAL Level 3 Emergency Lighting Systems Course for BS 5266 and BAFE SP203-4 work. This 1-day Cheshunt course covers design, installation, maintenance and emergency lighting certification requirements. EAL Level 3 Award approved.

Study TimeFixed course
1 days

Cheshunt, Hertfordshire

Tutor-led in-centre course
★★★★★ 4.9 / 5 · 1,000+ students trained
Duration1 Day + Exam
Price£329
Awarding bodyEAL
Qualification610/6121/9
- How you can take it

Book this course
or upgrade to the bundle.

Standard course

Emergency Lighting (BAFE SP203-4)

Take emergency lighting as a standalone add-on if you only need BS 5266-1 coverage.

Time in centre1 day
AwardSP203-4
  • EAL Level 3 Award (Qualification Number: 610/6121/9)
  • Covers BS 5266-1, BS EN 1838, and BS EN 50172
  • Small group training with individual support
£329
EAL Level 3 Award Accredited4.9 Star Reviews610/6121/9Cheshunt, Hertfordshire1 Day + Exam1,000+ Students Trained
- Who it is for

For every spark needing
a current certificate.

For electricians and fire-safety installers who need the EAL Level 3 Emergency Lighting Systems Course for BS 5266 and BAFE SP203-4 work. This 1-day Cheshunt course covers design, installation, maintenance and emergency lighting certification requirements.

01

Working electricians

Current goal610/6121/9

Add the recognised regulation or specialist certificate.

Best-fit route
02

Compliance teams

Current goal610/6121/9

Keep records and competence current for site work.

Advisor checked
03

Self-employed installers

Current goal610/6121/9

Broaden services and win higher-value jobs.

Progression ready
04

Refreshers

Current goal610/6121/9

Update knowledge without joining a long programme.

Flexible pathway
● Requirements

Clear entry. Clear outcome.

  • Be aged 16 or over (18+ to sign certificates)
  • Prior electrical qualifications or relevant practical experience
- Upcoming intakes

Reserve your place. Short-course spaces are limited.

Book a free consultation and we will map the shortest route from where you are today to the right qualification.

5Oct 2026
Full-Time
5th October 2026

Tutor-led route - 1 day

Last few spaces left

Don't see a date that works? - we run closed groups for teams of 10+.

- Course syllabus

Inside Emergency Lighting (EAL Level 3 / BAFE SP203-4). Every
unit mapped clearly.

Book a free consultation and we will map the shortest route from where you are today to the right qualification.

1 Day + Exam
0102030405
01610/6121/9

Emergency Lighting System Design

Purpose, legal responsibilities, illuminance levels, spacing, emergency duration, and system types.

EmergencyLightingSystem
02Unit 02

Installation & Commissioning

Wiring systems, circuit arrangements, control devices, commissioning processes, and certification.

CommissioningWiringsystems
03Unit 03

Inspection & Maintenance

Monthly, annual, and duration testing. Record keeping and fault reporting procedures.

InspectionMaintenanceMonthly
04Unit 04

EAL Level 3 Award (Qualification Number: 610/6121/9)

EAL Level 3 Award (Qualification Number: 610/6121/9). This is included as part of the course delivery.

EALLevelAward
05Unit 05

Covers BS 5266-1, BS EN 1838, and BS EN 50172

Covers BS 5266-1, BS EN 1838, and BS EN 50172. This is included as part of the course delivery.

Covers52661838
5Core areas
1 Day + ExamCourse length
6Assessments
- Assessment

How Emergency Lighting (EAL Level 3 / BAFE
SP203-4) is assessed.

Book a free consultation and we will map the shortest route from where you are today to the right qualification.

01Online

Emergency Lighting System Design

1 Day + ExamEAL Level 3 Award

Knowledge Check

02Online

Installation & Commissioning

1 Day + ExamEAL Level 3 Award

Knowledge Check

03Practical

Inspection & Maintenance

1 Day + ExamEAL Level 3 Award

Practical Assessment

04Online

Assessment Prep

Advisor confirmedEAL Level 3 Award

Knowledge Check

05Practical

Tutor Review

Advisor confirmedEAL Level 3 Award

Practical Assessment

06Online

Assessment Prep

Advisor confirmedEAL Level 3 Award

Knowledge Check

- Route comparison

Choosing Your Route

See what is included, what changes between routes, and whether a package gives you better value before choosing Emergency Lighting (EAL Level 3 / BAFE SP203-4).

Compare available routes for Emergency Lighting (EAL Level 3 / BAFE SP203-4)
CompareWhat changes?Option 1Emergency Lighting (EAL Level 3 / BAFE SP203-4)Option 2Fire Alarm & Emergency Lighting (EAL Level 3 Triple Award)RecommendedOption 3Domestic & Commercial Fire Alarm (EAL Level 3)
BS 5266-1 / BAFE SP203-4IncludedNot included
BS 5839-1 (commercial fire)Not includedIncluded
BS 5839-6 (domestic fire)Not includedIncluded
BAFE SP203-1 competencyNot includedIncluded
BAFE DS301 competencyNot includedIncluded
Duration1 Day4 Days
Price£329£1,198
- Successful Students

What Our Students Say

Hear directly from learners who used Learn Trade Skills to progress their electrical training route.

*****Paul S.
PS
5.0 RatingEmergency Lighting (EAL Level 3 / BAFE SP203-4)

Concise and informative. Covered everything I needed for emergency lighting design and certification - the BS EN 1838 luminance section made the difference on a tricky retail commission the following week.

*****Yusuf C.
YC
5.0 RatingEmergency Lighting (EAL Level 3 / BAFE SP203-4)

Done in a day, with the exam. Already SP203-1 registered for fire alarms - adding SP203-4 was the missing piece for our commercial fire safety contracts. Tutor was clear on BS 5266-1 design rules.

*****Michael R.
MR
5.0 RatingDomestic Installer Package

Left the office, joined the trade. Seven weeks in Cheshunt, first paid job the following Monday.

- Next step

Next steps after Emergency Lighting (EAL Level 3
/ BAFE SP203-4).

Book a free consultation and we will map the shortest route from where you are today to the right qualification.

- Frequently Asked

Everything you need
to know, upfront.

What is BAFE SP203-4 and why does it matter?

BAFE SP203-4 is the third-party certification scheme for the design, installation, commissioning, and maintenance of emergency lighting systems. BAFE-SP203-4-registered firms demonstrate competence to insurers, fire-risk assessors, and most commercial clients. To register your firm under SP203-4 your engineers need the EAL Level 3 Award covered by this course - it is the recognised competency route.

What standards does the course cover?

The course covers BS 5266-1:2016 (UK Code of Practice for emergency lighting), BS EN 1838:2024 (lighting applications - emergency lighting, the European luminance standard), and BS EN 50172:2024 (emergency escape lighting systems - testing and maintenance). Together these set the design rules (illuminance levels, escape route widths, anti-panic areas, high-risk task lighting), installation requirements, and ongoing test schedules.

Who can sign emergency lighting certificates?

BS 5266-1 requires emergency lighting commissioning and periodic test certificates to be signed by a competent person aged 18 or over. The EAL Level 3 Award is the standard evidence of competence for these signatures - and is what BAFE SP203-4 firms expect of their engineers. You can attend the course at 16+, but you must be 18+ to sign certificates.

What does the 1-day course cover?

System design fundamentals (purpose, statutory drivers, illuminance levels, emergency duration: 1h / 2h / 3h, escape route vs anti-panic vs high-risk lighting, BS EN 1838 luminance requirements), installation and commissioning (wiring systems, central battery vs self-contained, addressable vs maintained vs non-maintained), inspection and maintenance schedules (monthly function test, annual full-duration discharge test), and certification documentation. EAL Level 3 Award exam at end of day.

Do I need to be a qualified electrician?

Recommended but not formally required. The course assumes basic electrical knowledge (mains wiring, 230V AC, basic test instruments). Most attendees are practising electricians or fire-safety installers moving into emergency lighting work. If you are completely new to electrical work, take the Level 2 2365 Diploma first.

How does emergency lighting differ from regular lighting?

Emergency lighting is automatic luminaires that energise on mains failure to illuminate escape routes, anti-panic open areas, and high-risk task areas - keeping people safe during evacuation. Unlike regular lighting, it has a battery backup (typically 1-3 hours), is required by Fire Safety Order 2005 and Building Regulations, and must be tested monthly per BS EN 50172. Periodic inspection findings drive a separate certificate.

- Ready to advance?

Add the right qualification without delay.

Book the next short course and keep your records, competence and site opportunities current.

Call 01992 413 503
No obligation · usually same-day response · speak to a qualified advisor.

Before you start

Books & references

This list comes from the LTS course catalogue. Check it again before attending in case a publication edition changes.

Provided by the centre

These references are provided in-centre for study and assessment use. No purchase is required.

  • BS 5266 (Emergency Lighting)

    Please bring your own current physical copy. If you cannot bring one, contact Learn Trade Skills before the course so a centre loan copy can be reserved. Centre loan copies are for in-centre study and assessment only and must not be taken home, written in or annotated.

Prefer the full catalogue? View all course books and references.